Heating Ventilation and Air Conditioning Full Course - HVAC Course (Part 50)

 

  In this part of Full HVAC Course, We will learn about Control Strategies for HVAC Systems.

Control Strategies for HVAC Systems

No central air conditioning systems can be planned without an intensive information on the way things are to be controlled. Psychrometrics is useful in control framework plan, since the psychrometric graph which depicts the central air cycles
what's more, gives information to hardware choice likewise shows control focuses
furthermore, conditions normal.

Top 6 air conditioning Control Techniques to save energy

In this post we'll become familiar with the 6 main Control Systems for lessening energy utilization. These are control techniques to lessen cost and save energy. The control methodologies are customized into the succession of activity for the control of HVAC frameworks.

We'll find out about utilizing trim and respond (T&R) setpoint reset rationale for controlling chillers and air overseers. The energy investment funds from these systems change by geological region and building types.

Supply Air Temperature Reset

To save energy the supply air temperature can be reset higher when the interest is diminished. This will save money on blower energy use and permit additional opportunity for the utilization of the air side economizer.

Utilizing Trim and respond control rationale assuming no solicitation for cooling is shipped off the air overseer regulator, than the stockpile air temperature is managed by a set worth not set in stone by the software engineer. Suppose that assuming no solicitation is made the stock air temperature is reset 0.2°F, this would move our setpoint to 55.2°F. At regular intervals or anything that span is set by the controls software engineer the managing of the supply air temperature will happen until a solicitation is produced using a zone.

The VAV zone boxes can be customized to make a solicitation when any VAV box damper arrives at 90% open. At the point when the solicitation is sent, the inventory air temperature will answer by diminishing by a specific worth, picked by the software engineer, suppose by 0.3°F. On the off chance that our temperature was managed up to 58°F, before a solicitation was made, the solicitation would diminish our supply air temperature to 57.7°F.

On the off chance that numerous VAV boxes send demand simultaneously, the worth is increased by the quantity of solicitation. In the event that 4 VAV Boxes sent a solicitation for seriously cooling, the Stock Air Temperature could be reset by multiple times 0.3°F, for a sum of 1.2°F diminishing. The controls software engineer will restrict how much the supply air temperature can be diminished at any one time, regardless of the number of solicitation are sent for extra cooling. This permits framework soundness.

Frameworks utilizing an air-side economizer will have additional time when the economizer is being used in view of the stock temperature being set higher. This permits the open air to be utilized rather than the blower to give cooling, which saves money on energy.

Demand Control Ventilation

The reason why it is called Demand Controlled ventilation is that it controls how much ventilation in light of the interest. Demand changes with inhabitance levels, so some type of inhabitance checking will be utilized as the control system. Ventilation air is expected by ASHRAE standard 62.1, however giving ventilation air is energy concentrated and exorbitant. Giving just what's required can set aside on energy and cash.

With ASHRAE 62.1 the ventilation necessities or open air is expanded in view of the quantity of tenants and area of the space. Demand controlled ventilation depends on giving open air with respect to the inhabitance level.

Energy is squandered through molding inordinate measures of ventilation air when the inhabitance level is not exactly the plan greatest. By utilizing Demand controlled ventilation, the inhabitance level can be observed, and the amount of ventilation air changed descending as indicated by genuine tenant levels. Following the inhabitance level with DCV lessens energy utilization by just getting sufficient ventilation air to fulfill the ongoing degree of inhabitants, not the plan greatest.

Utilizing a meeting space for our model. In the event that the gathering room was intended for 125 individuals, however just the moderator is at present in the room hanging tight for participants. The CO2 screen would get the low amount of carbon dioxide and close the external air damper to match the tenant level. As additional participants show up to the gathering, the degree of CO2 increments, and the CO2 Screen gets this increment and sends an order for the External Air Damper to open more extensive, permitting more external air into the space. As, the tenants leave the framework will start to close the external air damper. 

Optimal Start

HVAC gear has frequently been arrangement to utilize a period clock or season of-day timetable to turn the framework on and off in light of a proposed inhabitance plan. The time clock will be set to begin the central air framework hardware before the inhabitants show up and to stop it at a prearranged time while the structure is booked to be empty. The timetable of when to turn on the central air gear in the first part of the day to guarantee the space is agreeable for the tenants is in many cases in view of the most obviously terrible summer or winter conditions. This sets out a freedom to save energy by giving an ideal beginning time when conditions are not at these pinnacle conditions.

With an Ideal Beginning technique the structure mechanization framework will choose the best, or ideal beginning time in light of the circumstances existing for that day. The structures control framework will decide how long, or how early the air conditioning hardware should be begun to guarantee the space is agreeable for the tenants when they show up. The structure robotization framework will keep the central air gear from beginning too soon, which is a lost cause. The controls will guarantee that the framework is begun with barely sufficient opportunity to have the space adapted when inhabitants show up, no sooner.

Utilizing the capacities of a structure mechanization framework to follow verifiable information and utilize that information for current circumstances is the manner by which this technique is carried out. The controls framework gets input from space sensors on the ongoing temperature and looks at this to the setpoint temperature. With verifiable moving information the structure computerization framework can decide how long the air conditioning hardware needs to race to compensate for any shortfall between this setpoint and the ongoing space temperature. The more prominent the Delta-T, the previous the air conditioning hardware will be begun.

This control procedure saves energy by ideally beginning gear and trying not to condition spaces to setpoint temperatures sooner than required. This saves money on functional hours of the air conditioning hardware, permitting the gear to endure longer.

Shorten HVAC Schedule

Frequently HVAC plans are set for longer time lengths then the genuine tenants require. Shortening the HVAC Schedules functions admirably with an ideal beginning and stop control procedure. This technique tries not to turn on central air hardware before they are required and rapidly switches them off when tenants are not planned to in the form. The structure mechanization framework learns with verifiable moving information when it's the best chance to turn gear on. The controls framework utilizes open air cools, indoor temperatures and set focuses for warming and cooling during involved mode.

There might be spaces inside the structure that work just on unambiguous days of the week. In the event that this space is on a similar framework as the consistently planned gear, it could result to give a different framework or strategy for controlling the molding of this space.

Working with ideal begin to decide the best opportunity to begin the gear, including night mishap temperatures, this procedure guarantees that the hardware is possibly running while the structure is involved.

Minimum VAV Box Damper Flow Reductions

Frameworks utilizing Variable Air Volume boxes have their dampers set to a base vacant situation to guarantee that there is dependably ventilation air as per ASHRAE 62.1. Frequently this base open setting is more prominent than the genuine CFM expected of the space, as the space will undoubtedly be affected by the inside load which will drive the damper more extensive open, refuting the base setpoint. Set the VAV box damper open to the base ordered to satisfy ASHRAE guideline 62.1 for ventilation and no more. See ASHRAE 62.1 Informative supplement "F" for a Worked on Ventilation Rate Computation for different zone recycling frameworks.

At the point when the base damper position is set too high, then fan and it is squandered to cool energy. A lot of cold air is being sent into the space, requiring extra energy to warm the air. This can be tried not to by lessen the base setpoint, and by utilizing this Base VAV Box Damper Stream Decrease system. This will obviously rely upon the space type and use.

Wider Dead Bands and Night Setbacks

By and large, this is the number 1 method for saving energy.

DeadBand

The deadband is the temperature range when the centralized air system is neither calling for warming or cooling.
By broadening the dead band, how much time that the central air framework would save energy would increment. In California zonal indoor regulators that are utilized to control both warming and cooling will be fit for giving a deadband of no less than 5°F.

Night Difficulty

While the structure is vacant during the evening time hours, the central air framework temperature can be misfortune in the scope of 6° to 10°F. This permits the structure to become hotter or cooler around evening time then during the day, yet tries not to allow it to get excessively far from setpoint. By permitting the air conditioning framework to increment or reduction from the setpoint, contingent upon whether in cooling or warming mode, the framework will come on less during the night while the structure is empty, subsequently saving energy.

The framework will come on just to keep away from outrageous temperature conditions. For example, if your typical daytime setpoint for cooling is 76°F, you could program the DDC framework to welcome on the air conditioning gear to cool the space late night or off plan assuming the structure temperature came to 86°F.

You can see that this works straightforwardly with the Ideal Beginning Control Technique which is to guarantee there is sufficient opportunity in the first part of the day to chill the space off to its typical setpoint. This is on the grounds that it was kept from keeping up with ordinary setpoint temperature of 76°F during the evening, consequently night mishap.

It's significant the framework be placed in the abandoned mode; this is to guarantee that the external air dampers are shut. Getting ventilation air in abandoned mode can increment energy utilization except if open air conditions are in the economizer range with the expectation of complimentary cooling of the space in summer.

Part 21 -- Click Here!!

Part 22 -- Click Here!!

Part 23 -- Click Here!!

Part 24 -- Click Here!!

Part 25 -- Click Here!!

Part 26 -- Click Here!!

Part 27 -- Click Here!!

Part 28 -- Click Here!!

Part 29 -- Click Here!!

Part 30 -- Click Here!!

Part 31 -- Click Here!!

Part 32 -- Click Here!!

Part 33 -- Click Here!!

Part 34 -- Click Here!!

Part 35 -- Click Here!!

Part 36 -- Click Here!!

Heat Load Calculation Guide 1

Heat Load Calculation Guide 2

Part 37 -- Click Here!!

Part 38 -- Click Here!!

How to Calculate External Static Pressure (ESP) with worked Example

How to Calculate Area of Sand Trap Louver with worked Example and detailed steps

Part 39 -- Click Here!!

Part 40 -- Click Here!!

Part 41 -- Click Here!!

Part 42 -- Click Here!!

Part 43 -- Click Here!!

Part 44 -- Click Here!!

Part 45 -- Click Here!!

Part 46 -- Click Here!!

Part 47 -- Click Here!!

Part 48 -- Click Here!!

Part 49 -- Click Here!!

Post a Comment

0 Comments